SETTING THE TEMPERATURE SWING (TEMPERATURE DIFFERENTIAL)
The Thermo Mode on the transmitter operates the appliance whenever the room temperature
varies a certain number of degrees from the set temperature. This variation is called the
“SWING” or TEMPERATURE DIFFERENTIAL. The factory preset swing temperature is 2º F (1º
C). To change the “swing” setting:
•
Press the SET button and the DOWN button simultaneously to display the current
“swing” setting in the set temp frame. The letter “S” will display in the room temp frame on
the LCD screen.
•
Press the UP or DOWN button to adjust “SWING” temperature (1º-3º F) (1º-2º C).
• To store the “swing” setting press the SET button, and the new “swing” setting will be
automatically programmed.
COMMUNICATION - SAFETY (C/S - TX)
This remote control has a COMMUNICATION –SAFETY function built into its software. It provides an extra margin of safety when the
Transmitter is out of the normal 20-foot operating range of the receiver.
At all times and in all OPERATING MODES, the transmitter sends an RF signal every 15 minutes, to the receiver, indicating that the
transmitter is within the normal operating range of 20 feet. Should the receiver NOT receive a transmitter signal every 15 minutes, the
receiver, will begin a 2-hour (120 minute) countdown timing function. If during this 2-hour period, the receiver does not receive a signal
from the transmitter, the receiver will shut down the appliance being controlled by the receiver. The receiver will then emit a series of
rapid “beeps” for a period of 10 seconds. Then after 10 seconds of rapid beeping, the receiver will continue to emit a single “beep”
every 4 seconds until a transmitter MODE button is pressed to reset the receiver.
CHILDPROOF “LOCK-OUT” - (CP)
This remote control includes a CHILDPROOF “LOCK-OUT” feature that allows the user to “LOCK-OUT” operation of the appliance from
the TRANSMITTER.
•
To activate the “LOCK-OUT” feature, press and hold the UP button and the SET button
together for 5 seconds. The letters “CP” will appear on the LCD screen.
•
To disengage the “LOCK-OUT”, press and hold the UP button and the SET button
together for 5 seconds or more, the letters “CP” will disappear from the LCD screen and
the transmitter will return to its normal operating condition.
• When the Transmitter is in “LOCK-OUT” mode, automatic functions (like thermostat) will
turn ON without interruption; only manual functions are prevented.
RECEIVER
Install the 4 AA-size batteries supplied with the unit. It is recommended that ALKALINE batteries always be used for this product. Be
sure the batteries are installed with the (+) and (-) ends facing the correct direction.
The remote receiver has a 3-position slide switch for selecting the mode of operation
ON/REMOTE/OFF
ON: will manually turn ON the appliance.
REMOTE: will allow use of handheld transmitter. If the system does not respond to the
transmitter on initial use, check the battery positions in the remote. If that does not
work, see the LEARNING TRANSMITTER TO RECEIVER section.
OFF: will disable the remote receiver.