REV. 8/3/11 Page 7 of 7
Skytech 3301P2
THERMO SAFETY FEATURE
If the receiver at anytime should reach 130 ºF, the receiver will automatically shut down and begin to beep 3 beeps every 2 seconds.
Once the temperature has dropped between 120ºF and 130ºF, the user can reactivate the appliance by pressing the MODE button, but
the beeping will continue until temperatures drop below 120ºF. This is to tell the user that the receiver needs to be relocated to reduce
temperatures.
If this situation happens, the receiver should be placed somewhere else where it will not reach temperatures in excess of 130ºF.
BATTERY LIFE
Life expectancy of the alkaline batteries in the transmitter and receiver should be at least 12 months.
Check and replace all batteries:
Annually.
When operating range becomes reduced.
When transmissions are not received by the remote receiver.
If the remote receiver batteries measure less than 5.3 volts (all four batteries in combination).
If the hand held transmitter batteries measure less than 2.5 volts (both batteries in combination).
TROUBLE SHOOTING
If you encounter problems with your fireplace system, the problem may be with either the fireplace itself or with the remote. Review the
fireplace manufacturer’s operation manual to make sure all connections are properly made. Then check the operation of the remote in
the following manner:
Make sure all batteries are correctly installed in the transmitter and receiver. Also check that the batteries are fully charged.
Check batteries in transmitter to make sure contacts are touching (+) and (-) ends of battery. Bend metal contacts in for tighter fit.
Be sure receiver and transmitter is within 20 to 25-foot operating range.
Keep receiver from temperatures exceeding 130 degrees F. Battery life will be shortened if exposed to high temperatures.
If receiver is installed in a tightly enclosed metal surrounding, the operating distance will be shortened.
Make sure the hand-held transmitter and remote receiver are communicating properly (see LEARNING TRANSMITTER TO
RECEIVER section).
FCC REQUIREMENTS
NOTE: THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED
MODIFICATIONS TO THE EQUIPMENT. SUCH MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO OPERATE THE
EQUIPMENT
For Technical Service, call:
U.S. INQUIRIES CANADIAN INQUIRIES
(888) 672-8929 or (260) 459-1703 (888) 472-3923
Web site: www.skytechsystem.com
MANUFACTURED EXCLUSIVELY FOR SKYTECH II, INC