Pre-Heating for Best Performance
The scan core will be heating when start working. We recommend pre-
heating RPLIDAR (Start the scan mode and the scan motor is rotating) for
more than 2 minutes to get the best measurement accuracy.
Ambient Temperature
RPLIDAR’s measurement resolution is sensitive to the ambient temperature.
Improper use may even damage the sensor. Please avoid using RPLIDAR in
extreme high temperature (>50℃) and too low temperature (<-10 ℃).
Ambient Light
Compared with RPLIDAR A series, RPLIDAR S2E performs better to resist
ambient light interference, which supports it to work properly in outdoor
environment.
Maintenance and Repairs
Please do not open the shell of the equipment for repair without
authorization, otherwise the warranty will be invalid.
Pay attention to keep the equipment shell clean during using to ensure the
normal operation of the lidar.