AC Output
STP5000TL-20 STP6000TL-20 STP7000TL-20
Rated power at 230V, 50Hz 5000W 6000W 7000W
Maximum apparent AC power
at cos phi = 1
5000VA 6000VA 7000VA
Rated grid voltage ∼3/N/PE, 230V /
400 V
∼3/N/PE, 230V /
400 V
∼3/N/PE, 230V /
400 V
AC voltage range* 160V to 280V 160V to 280V 160V to 280V
Nominal AC current at 220V 7.3A 8.7A 10.2A
Nominal AC current at 230V 7.3A 8.7A 10.2A
Nominal AC current at 240V 6.9A 8.3A 10.1A
Maximum output current 7.3A 8.7A 10.2A
Total harmonic distortion of the
output current with total har-
monic distortion of the AC volt-
age <2%, and AC power
>50% of the rated power
≤3% ≤3% ≤3%
Maximum output current under
fault conditions
12A 15A 17A
Rated power frequency 50Hz 50Hz 50Hz
AC power frequency* 50Hz / 60Hz 50Hz / 60Hz 50Hz / 60Hz
Operating range at AC power
frequency 50Hz
45.5Hz to 54.5Hz 45.5Hz to 54.5Hz 45.5Hz to 54.5Hz
Operating range at AC power
frequency 60Hz
55.5Hz to 64.5Hz 55.5Hz to 64.5Hz 55.5Hz to 64.5Hz
Displacement power factor
cosφ, adjustable
0.8underexcited to
1 to 0.8overexcited
0.8underexcited to
1 to 0.8overexcited
0.8underexcited to
1 to 0.8overexcited
Feed-in phases 3 3 3
Phase connection 3 3 3
Overvoltage category in accor-
dance with IEC60664-1
III III III
* depending on the configured country data set
11Technical Data
SMA Solar Technology AG
Operating ManualSTP5-12TL-20-BE-en-1560