Grid configurations TN-C, TN-S, TN-C-S, TT (when V
N_PE
< 20V)
Approvals and national standards, as per
06/2017*
AS 4777.2:2015, AS4777.3, CE,
CEI0-21:2016, C10/11:2012,
DINEN62109-1, EN50438, G59/3,
G83/2, IEC61727/MEA, IEC62109-2,
NENEN50438, NRS097-2-1, PPC, PPDS,
RD661/2007, RD1699:2011, SI4777,
UTEC15-712-1, VDE0126-1-1, VDE-AR-
N4105, VFR2013, VFR2014
* AS4777.3: If DRM support is specified, the inverter may only be used in conjunction with a Demand
Response Enabling Device (DRED).
CEI0-21: only permitted with external decoupling protection.
C10/11:2012: only possible if the three-phase line-to-line voltage is 400V.
IEC61727/MEA: applies only to the STP9000TL-20.
EN50438: does not apply to all national appendices of EN50438.
IEC62109-2: This standard requires that either the multifunction relay in the inverter is used as fault
indicator or that the inverter is connected to SunnyPortal and that the fault alert is activated in
SunnyPortal.
NRS97-2-1: This standard requires a separate label be attached to the AC distribution board to
indicate the AC-side disconnection of the inverter in case of a grid failure (for further details, see
NRS97-2-1, Sect. 4.2.7.1 and 4.2.7.2).
11.3 Protective Devices
DC reverse polarity protection Short-circuit diode
Input-side disconnection point ElectronicSolarSwitch, SUNCLIX DC connector
AC short-circuit current capability Current control
Grid monitoring SMAGridGuard4
Maximum permissible fuse protection 32A
Ground-fault monitoring for STP5000TL-20 /
6000TL-20 / 7000TL-20 / 8000TL-20 /
9000TL-20
Insulation monitoring: R
iso
>385kΩ
Ground-fault monitoring for STP 10000TL-20 /
12000TL-20
Insulation monitoring: R
iso
>200kΩ
All-pole sensitive residual-current monitoring unit Available
Grounding conductor monitoring Available
11.4 Climatic Conditions
Installation in accordance with IEC60721-3-3, Class4K4H
Extended temperature range -25°C to +60°C