AC Output
STP8000TL-20 STP9000TL-20 STP10000TL-20
Rated power at 230V, 50Hz 8000W 9000W 10000W
Maximum apparent AC power at
cosφ=1
8000VA 9000VA 10000VA
Rated grid voltage ∼3/N/PE,
230V / 400V
∼3/N/PE,
230V / 400V
∼3/N/PE,
230V / 400V
AC voltage range* 160V to 280V 160V to 280V 160V to 280V
Nominal AC current at 220V 11.6A 13.1A 14.5A
Nominal AC current at 230V 11.6A 13.1A 14.5A
Nominal AC current at 240V 11.1A 12.5A 13.9A
Maximum output current 11.6A 13.1A 14.5A
Total harmonic distortion of the output
current with total harmonic distortion
of the AC voltage <2%, and AC
power >50% of the rated power
≤3% ≤3% ≤3%
Maximum output current under fault
conditions
20A 22A 25A
Rated power frequency 50Hz 50Hz 50Hz
AC power frequency* 50Hz / 60Hz 50Hz / 60Hz 50Hz / 60Hz
Operating range at AC power fre-
quency 50Hz
45.5Hz to
54.5Hz
45.5Hz to
54.5Hz
45.5Hz to
54.5Hz
Operating range at AC power fre-
quency 60Hz
55.5Hz to
64.5Hz
55.5Hz to
64.5Hz
55.5Hz to
64.5Hz
Displacement power factor cosφ, ad-
justable
0.8underexcited
to 1 to
0.8overexcited
0.8underexcited
to 1 to
0.8overexcited
0.8underexcited
to 1 to
0.8overexcited
Feed-in phases 3 3 3
Phase connection 3 3 3
Overvoltage category in accordance
with IEC60664-1
III III III
* depending on the configured country data set