SMA Solar Technology AG 3 Product Description
Installation Manual SB30-50TL-21-IA-en-21 13
3.2 Symbols on the Inverter
Symbol Description Explanation
Inverter This symbol defines the function of the green LED.
It indicates the operating state of the inverter.
Observe the
documentation.
This symbol defines the function of the red LED.
It indicates a fault or disturbance. Please read the
manual to find information on how to remedy the
fault or disturbance.
Bluetooth This symbol defines the function of the blue LED.
It indicates that communication via Bluetooth is
activated.
QR Code
®
Links to additional information on the inverter can
be found at www.SMA-Solar.com.
Danger Observe the connection requirements for a
second protective conductor (see Section6.3.1
"Conditions for the AC Connection", page33).
Danger to life due to
high voltages in the
inverter
The capacitors in the inverter may be charged
with very high voltages.
Disconnect the inverter from voltage
sources (see Section 9.2) and wait
5 minutes before opening the upper lid, in
order to allow time for the capacitors to
discharge.