EasyManua.ls Logo

SMA SUNNY BOY 3600TL - Setting the Country Standard and Language Using the Rotary Switches

SMA SUNNY BOY 3600TL
120 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 Electrical Connection SMA Solar Technology AG
54 SB30-50TL-21-IA-en-21 Installation Manual
If the inverter is not set to the country of installation, there are several ways of configuring the required
country standard:
Setting via the two rotary switches (see Section6.5.2 "Setting the Country Standard and
Language using the Rotary Switches", page54).
Alternatively you can conduct the settings via the "CntrySet" or "Set country standard"
parameters via a communication product, once you have commissioned the inverter.
•If you require adjusted parameter settings for your installation site, you can change these with
the help of a communication product.
6.5.2 Setting the Country Standard and Language using the
Rotary Switches
1. Disconnect the inverter from voltage sources and open it (see Section9.2 "Disconnecting the
Inverter from Voltage Sources", page64).
2. Set the arrows on the rotary switches (A and B) to
the required position with a screwdriver
(see Section6.5.1 "Checking the Country
Standard", page50). Use a screwdriver with
blade width 2.5 mm.
Danger to life due to high voltages in the event of electricity grid failure
If you set the inverter to stand-alone grid operation "Off-Grid 50 Hz"/"Off-Grid 60 Hz", you are not
allowed to operate the inverter on the electricity grid, but only on the stand-alone grid, because the
inverter does not satisfy any country-specific standards and guidelines in this setting. In the event of
electricity grid failure, this will prevent the danger of backfeed.
If the inverter is set to "Off-Grid 50 Hz" or "Off-Grid 60 Hz", never operate the inverter directly
on the electricity grid.
E