9 Opening and Closing SMA Solar Technology AG
68 SB30-50TL-21-IA-en-21 Installation Manual
5. If an external DC switch-disconnector is in use, disconnect it.
6. If an ESS is used, check it for wear (see Section10.3 "Checking the Electronic Solar Switch for
Wear", page70).
7. If a multi-function relay is connected, switch on the supply voltage to the relay.
8. Switch the miniature circuit-breaker on.
9. Check whether the display and LEDs are indicating
a normal operating state (see Section7
"Commissioning", page57).
The inverter is now closed and in operation.
The ESS can be damaged if it is not connected correctly.
Plug the ESS in securely.
The handle of the Electronic Solar Switch must be
flush with the enclosure.
Check that the ESS is securely in place.