Technical data SMA Solar Technology AG
88 SB30TL_40TL_50TL-IA-IEN120231 Installation Guide
13 Technical data
13.1 Sunny Boy 3000TL
DC Input
* The maximum open circuit voltage, which can occur at a cell temperature of -10 °C, may not exceed the maximum input voltage.
AC Output
* Depends on country configuration
** Voltage surge resistance in accordance with IEC 60664-1
Maximum DC power at cos φ = 1 3,200 W
Maximum DC voltage* 550 V
MPP voltage range at AC nominal power 188 V … 440 V
DC nominal voltage 400 V
Minimum DC voltage 125 V
Start voltage, adjustable 150 V
Maximum input current 17 A
Maximum input current per string 17 A
Number of MPP trackers 1
Strings per MPP tracker 2
AC nominal power at 230 V, 50 Hz 3,000 W
Maximum AC apparent power 3,000 VA
Nominal AC frequency 220 V / 230 V / 240 V
Nominal AC current at 220 V / 230 V / 240 V 13.6 A / 13 A / 12.5 A
Maximum AC current 16 A
Total harmonic distortion of output current at
AC THD voltage < 2 %,
AC power > 0.5 AC nominal power
≤3%
AC voltage range* 180 V … 280 V
Nominal AC frequency* 50 Hz / 60 Hz
Operating range at nominal AC frequency 50 Hz 45 Hz … 55 Hz
Operating range at nominal AC frequency 60 Hz 55 Hz … 65 Hz
cos φ at nominal AC power 1
Supply phases 1
Connection phases 1
Overvoltage category** III