Technical Data SMA America, LLC
94 SB50US-80US-IA-en-36 Installation Manual
Efficiency
Ambient Conditions
Mechanical Data
Range of output power factor 0.95 … 1.0
Output power factor, nominal value 0.99
Peak inverter efficiency 97.0 %
CEC weighted efficiency at 208 V AC 95.5 %
CEC weighted efficiency at 240 V AC 95.5 %
CEC weighted efficiency at 277 V AC 96.0 %
Ambient temperature range SB 6000US − 13 °F … +113 °F
( − 25 °C … +45 °C)
Ambient temperature range SB 6000US-12 − 40 °F … +113 °F
( − 40 °C … +45 °C)
Width x height x depth 18
3
⁄
8
in. x 24
1
⁄
8
in. x 9
1
⁄
16
in.
(468 mm x 613 mm x 242 mm)
Weight 147 lb. (67 kg)
Noise emission 44 dB(A)