6 Mounting
SMA Solar Technology AG
Installation Manual 19SCCPXT-SCS_NR-IA-en-12
7. Insert the five upper screws of the rear panel into the threads and
tighten (TX 30, torque: 8Nm).
8. Make sure that the rear panel is correctly mounted.
6.6 Mounting the Kick Plate for the Sound Absorber
The kick plate must be mounted with an additional air duct on the rear side of the inverter.
Procedure:
1. Apply metal-free all-purpose paste to all threads in the base area.
2. Position and align the kick plate for the sound absorber on the
enclosure.
3. Screw the previously retained pan head flange screws into the threads.
4. Tighten the pan head flange screws on the kick plate (TX 30, torque: 8Nm).
6.7 Mounting the Ventilation Plate
The guide rails for the ventilation plate are located in the floor area of the inverter cabinet.
Procedure:
• Slide the ventilation plate into the guide rails in the inverter cabinet. The ventilation grid in the ventilation plate
should be facing the rear panel.
☑ The ventilation plate is flush with the inverter.
✖ The ventilation plate will not go all the way in?
• Grip the ventilation plate from underneath and press the middle part upwards while sliding it in.
6.8 Mounting the Kick Plate
A kick plate with an additional noise reduction must be mounted on the front side of the inverter.
Procedure:
1. Position and align the kick plate with soundproofing material on the enclosure.
2. Screw the previously retained pan head flange screws into the threads.
3. Tighten the pan head flange screws with a suitable screw driver (TX 30, torque: 8Nm).