Menu Item Factory Default Options
1 Pedestrian Mode Off On/Off
2 Lock Pulse Pulse/Hold (Magnetic)
3 Obstruction Setting 03 00 – 09
4 Open Speed 80% 50%-100% (by 5%)
5 Close Speed 80% 50%-100% (by 5%)
6 Motor Delay On (only for Dual Motor) On/Off
7 Photo Beam Off On/Off
7.1 PE Close Off (only for Photo Beam Mode) On/Off
7.2 Sequence Mode Off (only for Photo Beam Mode) On/Off
8 Auto Close Off (only for Photo Beam Mode) On/Off
8.1 Time Delay 30 secs 5-400 secs
8.2 PED Close Off On/Off
8.3 PED Time Delay 30 secs 5-400 secs
9 Transmitter Button PB=1 PD=2 PB, PD, OP, CL
10 Hands Free Learn On On/Off
11 Power Save Off On/Off
12 Close Delay 5 Sec 0-10 secs
-10-
Menu Quick Reference Guide
Use the table below as a reference to guide you through
the menu system and parameters.
Note: If Photo Beam (No. 7) is off next item is TX Button
Allocation (No. 9).
If PE Close (No. 7.1) is on then Sequence Mode
(No. 7.2) is not available.
Close Delay (No. 12) is only available when Dual
Motor is selected during set up.
© November 2011 Smart Openers Pty Ltd