Page #23 background imageLoading...
Page #23 background image
-22-
No.D-S-OMU0002-A
Initial value and selection range
Product No.
Parameter
Initial value
(value)
2
Initial value
(mm)
Selection range
Value/Range
D-MP025
Setpoint 1 (SP1)
250
12.5 mm
0 to 500
Setpoint 2 (SP2)
230
11.5 mm
Measuring range
0 to 500
25 mm
D-MP050
Setpoint 1 (SP1)
500
25 mm
0 to 1000
Setpoint 2 (SP2)
480
24 mm
Measuring range
0 to 1000
50 mm
D-MP100
Setpoint 1 (SP1)
1000
50 mm
0 to 2000
Setpoint 2 (SP2)
980
49 mm
Measuring range
0 to 2000
100 mm
D-MP200
Setpoint 1 (SP1)
2000
100 mm
0 to 4000
Setpoint 2 (SP2)
1980
99 mm
Measuring range
0 to 4000
200 mm
Common for
all ranges
Hysteresis
10
0.5 mm
0 to 400
2: 1value = 0.05 mm