EasyManuals Logo
Home>SMC Networks>Switch>SMC8024L2

SMC Networks SMC8024L2 User Manual

SMC Networks SMC8024L2
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #33 background imageLoading...
Page #33 background image
3-1
C
HAPTER
3
I
NSTALLING
THE
S
WITCH
Selecting a Site
TigerSwitch 10/100/1000 units can be mounted in a standard 19-inch
equipment rack or on a flat surface. Be sure to follow the guidelines below
when choosing a location.
The site should:
- be at the center of all the devices you want to link and near a power
outlet.
- be able to maintain its temperature within 0 to 40 °C (32 to 104 °F) and
its humidity within 10% to 90%, non-condensing
- provide adequate space (approximately five centimeters or two inches)
on all sides for proper air flow
- be accessible for installing, cabling and maintaining the devices
- allow the status LEDs to be clearly visible
Make sure twisted-pair cable is always routed away from power lines,
fluorescent lighting fixtures and other sources of electrical interference,
such as radios and transmitters.
Make sure that the unit is connected to a separate grounded power outlet
that provides 100 to 240 VAC, 50 to 60 Hz, is within 2 m (6.6 feet) of
each device and is powered from an independent circuit breaker. As with
any equipment, using a filter or surge suppressor is recommended.

Table of Contents

Other manuals for SMC Networks SMC8024L2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SMC Networks SMC8024L2 and is the answer not in the manual?

SMC Networks SMC8024L2 Specifications

General IconGeneral
BrandSMC Networks
ModelSMC8024L2
CategorySwitch
LanguageEnglish

Related product manuals