3. Technical data
SHZV tap-changer complies with IEC 60214-1: 2014 standard.
3.1 Type SHZV On-Load Tap Changer Technical Data
SHZVIII
SHZVI
Max. rated through current (A)
400*
*
400
600
*
*
Rated frequency (Hz)
50 or 60
3-phase Y-connection
Single-phase for any selectable
Max. rated step voltage (V)
4000
Rated step capacity
1500
1600
3000
1500
3000
4400
6000
Short-circuit
current test
(kA)
Thermal (3s)
8
12
8
12
24
30
Dynamic (peak)
20
30
20
30
60
75
Max. operating positions
18 without change-over selector; 35 with change-over selector
lation
to
ground
The highest voltage
72.5
126 170
52 362
Rated separate source AC
withstand voltage
(kV/50Hz,1min)
140 230 350 260 550
Rated lightning impulse
withstand voltage
350 550 750 1050 1175
selector
Categorized into B, C, D & DE four sizes
Mechanical life
Not less than 1,500,000 operations
life
Not less than 600,000 operations
Oil compartment
of diverter switch
Service
0.03 MPa
Leakage test
No leakage under 0.08 MPa for 24 hours
Over
pressure
Rupture disc bursts at 300 ± 20% KPa
Protective
relay
Set oil flow speed at 1.0m/s ± 10%
Motor drive unit
SHM-D or CMA7
Note:
1) SHZV with cylinder tap selector is applicable for the contact pitches of 10, 12 and 14 in linear, reversing and
coarse and fine regulating.
2) SHZV with cage tap selector is applicable for the contact pitches of 12,14,16 and 18 in linear, reversing and coarse
and fine regulating.
3) Marked* indicate that these tap changer’s Max operating positions can be 35 without change-over selector 107
with change-over selector.
Table3-1 Type SHZV (Cylinder Tap Selector) Series of On-Load Tap Changer Technical Data
.