3. Specifications
IEC 61010-1 Over Voltage:
CAT III 600V UL61010-1
Pollution Degree 2 CAT III 600V
Temperature for gauranteed accuracy: 23˚C +5˚C
DC VOLTS
Range Res. Accuracy
110.00mV 0.01mV
Impedance:
1.1000V 0.0001V +(0.5% of reading + 2 digits) 10MW
11.000V 0.001V Overload Protection:
110.00V 0.01V 600VDC or AC RMS
600.0V 0.1V
(45Hz to 100Hz Frequency Response AC 400mV Range)
AC VOLTS (45Hz to 450Hz Frequency Response All Other Ranges)
Range Res. Accuracy
110.00mV 0.01mV +
(1.2% of reading + 5 digits) Impedance:
1.1000V 0.0001V +(1.2% of reading + 3 digits) 10MW
11.000V 0.001V Overload Protection:
110.00V 0.01V +(1.5% of reading + 3 digits) 600VDC or AC RMS
600.0V 0.1V
8
(45Hz to 100Hz Frequency Response 200A to 400A)
AC AMPS (45Hz to 450Hz Frequency Response Below 200A)
Range Res. Accuracy
110A 0.01A +
(3.0% of reading + 10 digits)
400A 0.1A +(3.0% of reading + 5 digits)