16
Note: All user configurable settings are stored in non-volatile memory and are retained while power
is off.
Mode Setup
Mode setup menu allows user to enable/disable Torque THEN angle mode.
1. From Configure menu, press ENTER button while MODE SETUP selection is highlighted.
2. Mode Setup menu is displayed.
Menu Selections:
EXIT - Exits Mode setup menu and returns to Configure menu screen.
THEN DISABLED - Displays THEN Mode enable/disable screen.
3. Use UP /DOWN buttons to highlight menu selections.
4. Press ENTER button while EXIT menu selection is highlighted to return to Configure menu.
Enable/Disable Torque THEN Angle Mode
This function will allow user to enable or disable Torque THEN Mode.
1. From Mode Setup menu, use UP /DOWN buttons to highlight THEN DISABLED selection
(factory default) then press ENTER button.
2. TQ THEN ANGLE enable/disable screen is displayed.
3. Use UP /DOWN buttons to select ENABLE or DISABLE selection.
4. Press ENTER button to accept selection and exit to Mode Setup menu.
Note: Menu selection indicates current configuration (ENABLED or DISABLED).
Torque THEN Angle Mode
Torque THEN Angle mode is setup by first setting a target torque and units then a target angle before
selecting Torque THEN Angle mode. In Torque THEN Angle mode, when applied torque reaches
target torque, wrench automatically switches to angle mode for angle measurement. Progress lights
indicate applied torque progress while torque is measured and angle when angle is measured.
1. From target torque screen, use UP /DOWN buttons to set target torque and UNITS U
button to select torque measurement units then press ENTER button.
2. Angle target screen is displayed. Use UP /DOWN buttons to set target angle then press
ENTER button.
3. Torque THEN Angle mode screen is displayed.
4. Apply torque until target is reached then rotate wrench to target angle.
EXIT
MODE SETUPs
CALIBRATION
SET DATE/TIME
TQ THEN ANGLE
ENABLE
DISABLE
TQ THEN ANGLE
ENABLE
DISABLE