17
Note: UNITS U button can be used to select torque units while on Torque THEN Angle screen.
Note: Torque THEN Angle Presets are entered by pressing and holding Units button while on
Torque THEN Angle screen. Refer to "Adding a Torque Preset" and "Adding an Angle
Preset" in Basic section for parameter entry.
Note: Torque cycle is not recorded in memory unless both torque and angle reach targets.
Note: Red and yellow progress lights turn on if torque exceeds 110% of wrench full scale or if
angle exceeds target plus 4% in manual mode.
Note: Red and yellow progress lights turn on if torque exceeds maximum torque or if angle
exceeds maximum angle in Preset mode.
Calibration
Calibration menu is password protected. Contact your local Snap-on
Repair Center regarding Calibration menu.
Setting Date and Time
Set Date/Time function allows user to set real-time-clock date and time for time stamping data
records, recording last calibration date and notifying user of an expired calibration interval.
Note: When date and time is set for first time, In-Service date is also set and is used for calculating
initial calibration interval (see "Setting Calibration Interval" in Advanced Configuration
section).
1. From Configure menu, use UP /DOWN buttons to highlight SET DATE/TIME selection then
press ENTER button.
2. SET DATE screen is displayed with year highlighted.
3. Use UP /DOWN buttons to set year then press ENTER button to highlight month.
4. Use UP /DOWN buttons to set month then press ENTER button to highlight day.
5. Use UP /DOWN buttons to set day then press ENTER button.
6. SET TIME screen is displayed with Hour highlighted.
7. Use UP /DOWN buttons to set hour then press ENTER button to highlight minutes.
8. Use UP /DOWN buttons to set minutes then press ENTER button to highlight seconds.
9. Use UP /DOWN buttons to set seconds then press ENTER button.
10. Clock is set and Configure menu is displayed.
EXIT
MODE SETUP
CALIBRATION
SET DATE/TIME
00
TQ: 100.0 FT-LB
THEN AN: 45 DEG