104
M2 Scope/Meter M2 Scope/Meter Operations
Preset Selections
These options allow you to select from already configured scope setups for commonly tested
items. Six preset configurations are available; three for Preset A and three for Preset B. These
preset conditions are permanent and cannot be erased or modified. However, you can construct
and store additional presets within the D7 Diagnostic Tool as explained in the Scope and
Multimeter chapter of this manual.
Figure 8-16 Sample preset (Preset A, F2) screen
z To select a preset:
1. Use the F1 or S key to navigate to either Preset A or Preset B.
2. Press F2, F3, or F4 to load the desired preset.
The selected preset loads and the meter is ready for testing.
The F2, F3, and F4 fields on the screen are acronyms for the type of test the preset is configured
to perform. Interpret as follows:
Preset A:
CGI&S—ground controlled injectors and solenoids
LF AC—low frequency alternating current signals
HF AC—high frequency alternating current signals
Preset B:
PCI&S—power controlled injectors and solenoids
LF DS—low frequency digital signals
HF DS—high frequency digital signals
Values for the available presets are shown in the table below.
' ' ' '
 
&+
'&
P6
7$872
7&+
9
9'LY
7
($*4
1SFTFU" )'"$-'"$
Selection Position Timebase Scale Trigger Coupling Slope
Preset A
F2 (CGIS) 10 mS 50 Volts 8 Volts DC Negative
F3 (LF AC) 50 mS 20 Volts 0 Volt AC Positive
F4 (HF AC) 10 mS 20 Volts 0 Volt AC Positive