Trace Details
The Trace Details section displayed at the base of the screen can be used to quickly adjust
settings for capturing the trace. The Trace details are accessed using either the Data icon on the
upper toolbar or the Touch and Grow icon (fingerprint) icon on the Playback toolbar. Both icons
function the same and cycle the Trace Details selection through three states:
Displayed—trace settings are displayed in this mode
Expanded—trace settings are displayed in a larger format in this mode
Off—trace settings are not displayed in this mode
Adjustments are made by selecting the item to be changed on the touch screen. A dash (–)
indicates a function that is not selected, and an icon displays to indicate an active function.
1— Peak Detect on
2— Inverted trace
3— Coupling AC on
4— Sweep setting
5— Trigger set on the rising edge
6— Trigger setup
Figure 9-9 Sample Touch and Grow display