Set Lengths for Codabar (18h & 19h)
One Discrete Length : Length 1 = value , Length 2 = 0.
Two Discrete Lengths : Length 1 > Length 2.
Length Within Range : Length 2 > Length 1.
Any Length : Length 1 = 0, Length 2 = 0.
R : 00 00 05 C7 04 00 18 S1 S2
R : 00 00 05 C7 04 00 19 S1 S2
W : 00 00 07 C6 04 00 FF 18 05 S1 S2
Length 1
W : 00 00 07 C6 04 00 FF 19 37 S1 S2
Length 2
Triple Setting , input 2 digits , Range : 00~55.
CLSI Editing (36h)
R : 00 00 05 C7 04 00 36 S1 S2
W : 00 00 07 C6 04 00 FF 36 01 S1 S2
Enable CLSI Editing
W : 00 00 07 C6 04 00 FF 36 00 S1 S2
*Disable CLSI Editing
NOTIS Editing (37h)
R : 00 00 05 C7 04 00 37 S1 S2
W : 00 00 07 C6 04 00 FF 37 00 S1 S2
*Disable NOTIS Editing (保留 abcd)
W : 00 00 07 C6 04 00 FF 37 01 S1 S2
Enable NOTIS Editing (移除 abcd)