4.Passive Mode
OK
Self-use Mode
In Self-use mode, inverter will automatically charge & discharge the battery.
1) If PV generation = LOAD
consumption (ΔP < 100W) inverter
won’t charge or discharge the battery.
2) If PV generation > LOAD
consumption, the surplus power will
be stored in the battery.
3) If the battery is full(or already at Max
Charge Power), excess power will be
exported to the grid.
4) If PV generation < LOAD
consumption, it will discharge the
battery to supply power to load.
5) If PV generation + Battery < LOAD
consumption, inverter will import
power from the grid.
Time-of-use Mode
If electricity is more expensive in high demand time (peak rate) & electricity