OPERATION OF THE DEVICE
98 HYD 5K...20KTL-3PH
DisCharge
Power
02500 W
7.3.4 Passive Mode
The passive mode is used in systems with external energy
management systems. The inverter's operation will be controlled by
the external controller using the Modbus RTU protocol. Please contact
SOFARSOLAR if you need the Modbus protocol definition for this
device.
7.3.5 EPS Mode
With the EPS Mode the inverter can provide energy to the loads
without public grid connection or during grid outages.
The EPS mode is only available when a battery is connected to the
inverter.
If PV generation equals the load
consumption (ΔP < 100 W), the
inverter won't charge or discharge
the battery