TROUBLESHOOTING HANDLING
80 SOFAR 3 ... 6KTLM-G3
ID152
SafetyVerFrauIt
If the error persists,
contact technical support.
ID153
SciCommLose(DC)
SCI communication
error (DC)
ID154
SciCommLose(AC)
SCI communication
error (AC)
ID155
SciCommLose(Fuse)
SCI communication
error (fuse)
ID156
SoftVerError
Inconsistent
software versions
Download the latest
firmware from the website
and launch the software
update. If the error
persists, contact technical
support.
ID157
BMSCommunicatonFault
Lithium battery
communication
error
Make sure your battery is
compatible with the
inverter.
CAN communication is
recommended. Check the
communication line or the
connection of the battery
and the inverter for errors.
ID161
ForceShutdown
Forced shutdown
The inverter has been
forcibly disconnected.
ID162
RemoteShutdown
Remote shutdown
The inverter is shut down
remotely.
ID163
Drms0Shutdown
DRM 0 shutdown
The inverter is running
with a Drms0 shutdown.
ID165
RemoteDerating
The inverter has
reduced its power
due to remote
control
This message is for
information and is not an
error

Related product manuals