TROUBLESHOOTING HANDLING
SOFAR 3 ... 6KTLM-G3 81
ID166
LogicInterfaceDerating
The inverter has
reduced its power
due to the digital
inputs
ID167
AlarmAntiRefluxing
Power reduction
due to current
sensor or
SmartMeter
configuration
ID169
FanFault1
Fan 1 fault
Check if the
corresponding fan of the
inverter is running
normally.
ID170
FanFault2
Fan 2 fault
ID171
FanFault3
Fan 3 fault
ID172
FanFault4
Fan 4 fault
ID173
FanFault5
Fan 5 fault
ID174
FanFault6
Fan 6 fault
ID175
FanFault7
Fan 7 fault
ID176
MeterCommLose
Communication
fault with meter
unit
Check communication to
meter
ID177
BMS OVP
BMS overvoltage
alarm
Internal error in the
connected lithium battery.
Switch off the inverter
and the lithium battery,
wait 5 minutes and then
switch the components on
again.
If the error persists,
contact Technical
Support.
ID178
BMS UVP
BMS Undervoltage
alarm
ID179
BMS OTP
BMS High
temperature
warning
ID180
BMS UTP
BMS low
temperature
warning
ID181
BMS OCP
BMS overload
warning during

Related product manuals