SOFAR 60-80KTLX-G3 User manual
Copyright © Shenzhen SOFARSOLAR Co., Ltd.
50
update success, the system will start initialization, the LED will display"System is
starting...". When the initialization is finished, the LED screen shows recoverable
fault (since the ac breaker is still off, the machine does not detect the power grid, so
recoverable fault will be displayed)
Step 9: After the update is completed,turn off the DC breaker, wait for the LCD
screen extinguish, then recover the communication waterproof and then turn on the
DC breaker and AC breaker again, the inverter will enters the running state.
Note: If screen shows “Communication fail”, “xxx Update fail”,
“xxx file error”. This means the software upgrade failed. Please turn off the DC
switch, waiting for 5 minutes(Discharge the capacitance) , then continue to update
from step 5.