To connect the RS485 communication bus:
1. Remove the inverter cover as described in
Removing the Inverter Cover
on page 70.
2. Remove the seal from one of the openings in communication gland #2 and insert
the wire through the opening.
3.
Pull out the 6-pin RS485 terminal block connector, as shown below:
Figure 25: The RS485 terminal block
4.
Loosen the screws of pins A(+), B(-), and G on the left of the RS485 terminal block
(RS485-1 or RS485-2).
Figure 26: RS485 terminal block
5.
Insert the wire ends into the G, A and B pins shown above. Use Four- or six-wire
twisted pair cable for this connection.
You can use any color wire for each of the A, B and G connections, as long as:
The same color wire is used for all A pins the same color for all B pins and
the same color for all G pins
The wire for G is not from the same twisted pair as A or B.
6.
For creating an RS485 bus - connect all B, A and G pins in all inverters. The following
Chapter 7: Setting Up Communication 75
Three Phase System Installation Guide MAN-01-00057-4.1

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SolarEdge SE10k and is the answer not in the manual?

SolarEdge SE10k Specifications

General IconGeneral
AC Output Power10000 W
Maximum Efficiency98.3%
CoolingNatural Convection
Protection RatingIP65
Rated AC Power10000 W
Max. DC Power13500 W
CEC Weighted Efficiency97.5%
TopologyTransformerless
Number of MPP Trackers2
Warranty12 years
Operating Temperature Range-25°C to 60°C
Communication InterfacesRS485, Ethernet
DC Overvoltage ProtectionType 2

Related product manuals