9. Maintenance
9 Maintenance
■ If the ambient temperature for storage is -4°F~122°F/-20℃~50℃, recharge the
batteries at least once every 3 months.
■ If the ambient temperature for storage is 32°F~104°F/0℃~40℃, recharge the
batteries at least once every 12 months.
■ If the battery(ies) has(have) not been used for more than 9 months, the
battery(ies) must be charged to at least SOC 50 % each time.
■ For the first installation, the interval among manufacture dates of batteries shall
not exceed 3 months.
■ If a battery is replaced or added for capacity expansion, each battery's SOC
should be consistent. The max. SOC difference should be between ±5%.
■ If users want to increase their battery system capacity, please ensure that the
SOC of the existing system capacity is about 40%. The manufacture date of
the new battery shall not exceed 6 months; in case of exceeding 6 months,
please charge the new battery to around 40%.
■ In the allowable range, the relative humidity range should be between 0% and
90% RH.
10. Disclaimer
10 Disclaimer
54
55
Triple Power protects this product under warranty when it is installed and used as
listed in this manual. Violation of the installation procedure or use of the product in
any way not described in this manual will immediately void all warranties on the
product.
Triple Power does not provide warranty coverage or assume any liability for direct
or indirect damages or defects that result from the following causes:
■ Force majeure (flooding, lightning strike, overvoltage, fire, thunderstorm,
flooding etc.);
■ Improper or noncompliant use;
■ Improper installation, commissioning, start up or operation (contrary to the
guidance detailed in the installation manual supplied with each product);
■ Inadequate ventilation and circulation resulting in minimized cooling and natural
air flow;
■ Installation in a corrosive environment;
■ Damage during transportation;
■ Unauthorized repair attempts;
■ Failure to adequately maintain the equipment. An on-site inspection by a
qualified technician is possible following 120 months of continuous use
Warranty claims made beyond 120 months from date of commissioning may
be declined if it cannot be demonstrated that the equipment has been
adequately maintained;
■ External influence including unusual physical or electrical stress (power failure
surges, inrush current, etc.);
■ Use of an incompatible inverter or devices;
■ Connect to other brands of inverter without authority from our company.