g) Advanced
All the advance setting can be set here, such as battery, grid, EPS and so on.
Advanced” is divided four parts: On-grid, Battery, Reset, User-define. And every
part has lower level parts.
Pls contact with your installer or factory for the installer password to enter.
On-grid
Battery
Paralles Setting
Advanced
* Please note that when inverter has DSP communication failed, all the advanced
setting will be hidden and invalid expect battery awaken.
DSP-COMM failed
>Battery
Advanced
>Battery Awaken
Charger
NO
e) Relay Control
Relay Control is an optional function which can control designated load
intelligently by consuming the surplus energy when feed in power reaches
certain value.
This function can only be achieved with solax product “Smart Plug”.
For specific operation, please refer to “ Smart Plug user manual”.
>Relay1 Setting
>Relay2 Setting
Relay Control
58
59
>
f )Self Test (applies to CEI 0-21 only)
The self test function allows user to test the following items.ALL test , ” Ovp(59.S2) test”,
Uvp(27.S1) test”, ” Uvp(27.S2) test, ” Ofp(81>.S1) test”, ” Ufp(81<.S1) test”,
Ofp(81>.S2) test, ” Ufp(81<.S2) test”, ” Ovp10(59.S1) test”.
In the self test interface, user can test choose ALL test or individual test item.
Please make sure the inverter is grid-tied before testing test.
For all test, it needs about 6 minutes. And it will displaysuccess” then “Pass on the
display.
For individual test item, it needs about several seconds or minutes.
Click test report to obtian all items test result.
ALL Test
Test report
Uvp(27.S1) test
Ft: 51.50Hz Tt:1000ms
Fs: 0.00Hz To: 998ms
F0: 0.00Hz pass
>Ofp2(81>.S2)result
Vt: 264.5V Tt: 300ms
Vs: 0.0V To: 200ms
V0: 0.0V pass
>Ovp2(59.S2)result
Vt: 92.0V Tt: 200ms
Vs: 0.0V To: 196ms
V0: 0.2V pass
>Ofp2(27.S2)result
Vt: 195.5V Tt: 400ms
Vs: 0.0V To: 200ms
V0: 0.0V pass
>Uvp2(27.S1)result
Ft: 50.50Hz Tt: 100ms
Fs: 0.00Hz To: 96ms
F0: 0.2Hz pass
>Ofp2(81>S1)result
Ft: 49.50Hz Tt: 100ms
Fs: 0.00Hz To: 98ms
F0: 0.02Hz pass
>Ufp2(81<.S1)result
Ft: 47.50Hz Tt: 400ms
Fs: 0.00Hz To: 3999ms
F0: 0.02Hz pass
>Ufp2(81<.S2)result
Vt: 253.0V Tt: 600ms
Vs: 0.0V To: 598ms
V0: 0.0V pass
>Ovp10(59.S1)result
Setting Setting
(g-1-1)
(g-1-2)
(g-1-3)
(g-1-4)
(g-1-5)
(g-1-6)
(g-1-8)
(g-1-7)
On-grid
(g-1-9)
(g-1-10)
Safety
Power Factor
Grid
Export Control
Remote Control
Grid Service
Phase Power Balance
H/LVRT Function
PU Function
DRM Function
Power Limit
(g-1-11)
Hot Standby Settings
(g-1-12)