Power Factor
Back OKBack OK
Mode:
Type:
Value:
[ Constant cosφ(P) ]
[ Ind ]
[ 0.90 ]
Power Factor
Mode:
Value:
[ Power Limit ]
[ 0.85 ]
F)Grid Setting
Grid setting is to set the limited parameter of the public grid.It has 8 parameters
to set.
-Enter the “Grid Setting”by select the “Grid Setting”with cursor on the setting
interface and press “OK to conrm.
-Enter the “Grid Setting”interface.Move the cursor to the parameter you want
to set by press up and down button.Conrm the select by pressing ‘OK’.
-The cursor will ash,press the up and down button to increase or decrease the
value and press “Ok”to conrm.
-Press the down button when the cursor is at the bottom of the screen,the
screen will jump to the next page.
Grid Setting
Back OK
Page - 1/2
Vac High:
Vac Low:
Vac High Slow:
Vac Low Slow:
[ 240 V ]
[ 210 V ]
[ 235 V ]
[ 215 V ]
Grid Setting
Back OK
Page - 2/2
Fac High:
Fac Low:
Fac High Slow:
Fac Low Slow:
[ 55.00 Hz ]
[ 40.00 Hz ]
[ 50.00 Hz ]
[ 45.00 Hz ]
G)Reset
Reset function can reset E-taday and error log.
-Enter the interface by selecting the “Reset”with the cursor on the setting interface
and press”OK”to conrm.
-Select”Reset E-todayor “Reset error log”and press”OK”to conrm.
-After get into Reset E- today or reset error log interface.Press OK to reset.
Reset
Back
Reset E-today
Reset Error Log
H)Safety
Safety can set the different countriessafety rule here.
-Enter the safety by select the “Safety”on the setting interface.
-Press up and down to choose the different country,press”OK” to conrm.
-Move the cursor to “Back”and press OK to get back to the setting interface.
Safety
Back
Germany
Information
Information interface display the main information about inverter.Such as the
Total generated power.The current temperature inside the inverter and the total
run time.
-Enter the “Information”by selecting the “Information”with cursor on the menu
interface and press”OK”to conrm.
-Move the cursor to ‘Back” and press OK to get back to the menu interface.
Information
Back
Yield Total: 2145KWh
Temperature: 55.4°C
Run Time: 187h
Safety Code: Germany
OK
About
About interface display the version No, and the series No, of the inverter.
-Enter th About by selecting the “About” with cursor on the menu interface and
press “OK to conrm.
-Move the cursor to”Back and press”OK to get back to the menu interface.
About
Back
DSP1: 1.0
DSP2: 1.0
CPU3: 1.0
SN: XXXX-XXXX-XXXX-XX
39
38
6 Operation Method 6 Operation Method