If your inverter's information panel is not displaying a Fault light, check the
following list to make sure that the present state of the installation allows proper
operation of the unit.
• Is the inverter located in a clean, dry, and adequately ventilated place?
• Have the DC input breakers been opened?
• Are the cables adequately sized and short enough?
• Are the input and output connections and wiring in good condition?
• Are the configurations settings correct for your particular installation?
• Are the display panel and the communications cable properly connected
and undamaged?
Contact SolaX Customer Service for further assistance. Please be prepared to
describe details of your system installation and provide the model and serial
number of the unit.
7.2 Routine Maintenance
Inverters do not need any mainteinance or correction in most condition,but if
the inverter often loses power due to overheating,this can be the following
reason:
• The cooling fins on the rear of house are coverd by dirts.
Only trained and authorized professional personnel who are familiar with
the requirements of safety was allowed to perform servicing and
maintenance work.
Safety checks
Safety checks should be performed at least every 12 mouths by manufacturer's
qualified person who has adequate training,kownledge,and practical experience
to perform these tests.The data should be recorded in an equipment log.If the
device is not functioning properly or fails any of test,the device has to be
repaired.For safety check details ,refer to this manual,section 2 Safety instruction
and EC Directives.
Maintain periodically
Only qualified person may perform the following works.
During the process of using the inverter,the manage person shall examine and
maintain the machine regularly.The concrete operations are follow.
1: Check that if the inlet and oulet of the inverter are blocked,if the fans work
normally,the machine can be cleaned and absorbed dust when necessary.This
work shall be check time to time.
2: Check that if the indicators of the inverter are in normal state,check if the
keys of the inverter are in normal state,check if the display of the inverter is
●
●
normal.This check should be performed at least every 6 months.
3: Check that if the input and output wires are damaged or aged.This check
should be performed at least every 6 months.
4: You should get the inverter panels cleaned and their security checked at l
east every 6 months.
Clean the ventilation grids
The inverter takes cooling air in form the grid and below it out again through
the grid with the fan,If the ventilation grid is covered with dust will directly
result in bad ow of air to the inverter.Clean the ventilation grids if they are dirty.
“The ventilation grids can not be removed for long.Since the
ventilation grids takes the responsibility to protect the invereter
against the entrance of insects.
NOTE!
• Disconnect the inverter from DC Input and AC output.
• Remove all connection cables from the inverter.
• Open the anti-theft lock.
• Remove the inverter from the bracket.
• Remove the bracket if necessary.
8.1 Dismantling the Inverter
8 Decommissioning
If possible, please pack the inverter with the original packaging.
If it is no longer available, you can also use an equivalent carton that meets
the following requirements.
• Suitable for loads more than 50kg.
• With handle.
• Can be fully closed.
8.2 Packaging
Store the inverter in dry place where ambient temperatures are always between
-20 °C - +60 °C.
8.3 Storage
45
44
8 Decommissioning 7 Troubleshooting