9.1 Technical data
Max voltage (Volts)
Startup voltage (Volts)
Operating MPPT voltage range (Volts)
Max usable input current per MPPT (Amps)
Max short circuit input current (Amps)
Number of M P P T
Nominal output power(Watts)
Nominal grid voltage (Volts)
Max. overcurrent protection device(Amps)
Rated output current(Amps)
Output power factor range
Grid current THD
Nominal grid frequency (Hertz)
Operating frequency range (Hertz)
Peak efficiency
CEC weighted efficiency
MPPT efficiency
Max power per MP P T (Watts)
Operating voltage range (Volts)
Rapid shutdown
Model
Dimensions(cm)
Weight(kg)
Topology
Ambient operating temperature range
Enclosure type
Noise emission(typical)
Cooling concept
Max. operating altitude without derating
Designed lifetime
Connection
Comliance
Operating surroundings humidity
310W*373H*160D
Optional
600
50...500
11
17.2
1
230/240
160...285V
10
0.8leading...0.8lagging
<1.5%
50/60
47...52 or 57...62
97.2%
96.5%
>99.5%
7.4kg
Transformerless
Ip65
<20 dBA
Natural convection
4000m
>20 years
0...100% Condensing
Mc4 connector and Ip67 rated plug
Solis-mini-1000-4G
60
1000
4.3
Inputs per MPPT
1
-25℃...60℃
Display
Interface
Warranty Terms
LCD, 2×20 Z.
RS 485, WIFI/G P R S (optional)
5 Years STD (Extendable to 20 Years)
Max. output power(Watts)
1100
EN50438, G83/2, AS4777.2:2015,
VDE0126-1-1, I E C61727, VDE N4105
1200
Max. Inverter Backfeed Current to the Array (Adc)
Current(inrush)(Peak and Duration)
Max. Output Fault Current(Aac)
0
0
35
Max. apparent output power(VA)
1100
Max voltage (Volts)
Startup voltage (Volts)
Operating MPPT voltage range (Volts)
Max usable input current per MPPT (Amps)
Max short circuit input current (Amps)
Number of M P P T
Nominal output power(Watts)
Nominal grid voltage (Volts)
Max. overcurrent protection device(Amps)
Rated output current(Amps)
Output power factor range
Grid current THD
Nominal grid frequency (Hertz)
Operating frequency range (Hertz)
Peak efficiency
CEC weighted efficiency
MPPT efficiency
Max power per MP P T (Watts)
Operating voltage range (Volts)
Rapid shutdown
Model
Dimensions(cm)
Weight(kg)
Topology
Ambient operating temperature range
Enclosure type
Noise emission(typical)
Cooling concept
Max. operating altitude without derating
Designed lifetime
Connection
Comliance
Operating surroundings humidity
310W*373H*160D
Optional
Solis-mini-700-4G
900
600
50...500
11
17.2
1
700
230/240
160...285V
10
3.0
0.8leading...0.8lagging
<1.5%
50/60
47...52 or 57...62
97.2%
96.5%
>99.5%
7.4kg
Transformerless
Ip65
<20 dBA
Natural convection
4000m
>20 years
0...100% Condensing
Mc4 connector and Ip67 rated plug
60
Inputs per MPPT
1
-25℃...60℃
Display
Interface
Warranty Terms
LCD, 2×20 Z.
RS 485, WIFI/G P R S (optional)
5 Years STD (Extendable to 20 Years)
Max. output power(Watts)
800
EN50438, G83/2, AS4777.2:2015,
VDE0126-1-1, I E C61727, VDE N4105
Max. Inverter Backfeed Current to the Array (Adc)
Current(inrush)(Peak and Duration)
Max. Output Fault Current(Aac)
0
0
35
Max. apparent output power(VA)
800