10. Specifications
.47..46.
10. Specifications
Max. DC input voltage (Volts)
MPPT voltage range (Volts)
Max. input current (Amps)
MPPT number/Max input strings number
Rated grid voltage (Volts)
Rated output current (Amps)
Power Factor (at rated output power)
Operating frequency range (Hertz)
Max.efficiency
EU efficiency
Model
Dimensions
Weight
Topology
310W*563H*219D (mm)
1100
2/4
50/60
18.8kg
Transformerless
Rated output power (Watts)
Max. output power (Watts)
Max. apparent output power (VA)
600
15000
16500
16500
22.8/21.7
S5-GR3P15K
THDi (at rated output power)
160...1000
Start-up voltage (Volts)
180
Max short circuit input current (Amps)
Rated DC voltage (Volts)
Rated grid frequency (Hertz)
3/N/PE, 220/380, 230/400
Max. output current (Amps)
23.8
45...55 or 55...65
>0.99 (0.8 leading - 0.8 lagging)
Operating ambient temperature range
Ingress protection
Noise emission (typical)
Cooling concept
Max.operation altitude
<60 dBA
Intelligent redundant fan-cooling
4000m
Self consumption (night)
-25℃.. .+60℃
Relative humidity
0~100%
Grid connection standard
Display
Communication connections
Warranty Terms
LCD, 2×20 Z.
5 Years (Extend to 20 Years)
G98 or G99, VDE-AR-N 4105 / VDE V 0124,
EN 50549-1, VDE 0126 / UTE C 15 / VFR:2019,
RD 1699 / RD 244 / UNE 206006 / UNE 206007-1,
CEI 0-21, C10/11, NRS 097-2-1, TOR,
EIFS 2018.2, IEC 62116, IEC 61727, IEC 60068,
IEC 61683, EN 50530
Safety/EMC standard
IEC 62109-1/-2, EN 61000-6-1/-2/-3/-4
DC connection
AC connection
MC4 connector
Quick connection plug
32+32
40+40
98.6%
98.0%
<1 W
<2%
Optional USB* :only for the brazilian market
RS485, DO, DI, Optional: Wi-Fi, GPRS,USB*
IP66
Max. DC input voltage (Volts)
MPPT voltage range (Volts)
Max. input current (Amps)
MPPT number/Max input strings number
Rated grid voltage (Volts)
Rated output current (Amps)
Power Factor (at rated output power)
Operating frequency range (Hertz)
Max.efficiency
EU efficiency
Model
Dimensions
Weight
310W*563H*219D (mm)
1100
2/4
50/60
20.0kg
Rated output power (Watts)
Max. output power (Watts)
Max. apparent output power (VA)
600
17000
18700
18700
25.8/24.6
THDi (at rated output power)
160...1000
Start-up voltage (Volts)
180
Max short circuit input current (Amps)
Rated DC voltage (Volts)
Rated grid frequency (Hertz)
3/N/PE, 220/380, 230/400
Max. output current (Amps)
27.0
45...55 or 55...65
>0.99 (0.8 leading - 0.8 lagging)
Operating ambient temperature range
Ingress protection
Noise emission (typical)
Cooling concept
Max.operation altitude
<60 dBA
Intelligent redundant fan-cooling
Self consumption (night)
-25℃.. .+60℃
Relative humidity
0~100%
Topology
Transformerless
Grid connection standard
Display
Communication connections
Warranty Terms
LCD, 2×20 Z.
5 Years (Extend to 20 Years)
G98 or G99, VDE-AR-N 4105 / VDE V 0124,
EN 50549-1, VDE 0126 / UTE C 15 / VFR:2019,
RD 1699 / RD 244 / UNE 206006 / UNE 206007-1,
CEI 0-21, C10/11, NRS 097-2-1, TOR,
EIFS 2018.2, IEC 62116, IEC 61727, IEC 60068,
IEC 61683, EN 50530
Safety/EMC standard
IEC 62109-1/-2, EN 61000-6-1/-2/-3/-4
DC connection
AC connection
MC4 connector
Quick connection plug
32+32
40+40
98.7%
98.1%
<2%
<1 W
S5-GR3P17K
RS485, DO, DI, Optional: Wi-Fi, GPRS,USB*
IP66
Optional USB* :only for the brazilian market
4000m