S201 AFM
3 - EMERGENCY PROCEDURES
3.4 - SMOKE AND FIRE
27/06/2019
SONAIR-S2-D-MAN-006
Rev. : A
3.4 SMOKE AND FIRE
3.4.1 ENGINE FIRE
1. Throttle - full power.
2. Fuel selector - close.
3. Auxiliary Fuel pump - off.
4. Cabin heat - close.
5. Main Fuel Pump - pull circuit Breaker
6. Fresh air venting - open (except if smoke comes in via those
vents)
7. Ignition - switch off after the fuel in carburettors is
consumed and engine has shut down.
8. Emergency landing - refer to 3.3.4 EMERGENCY LANDING WITH
ENGINE OFF
WARNING
After engine fire, never attempt to re-start the engine!
NOTE
Estimated time to empty carburetors after pumps are
stopped is 15 seconds