S201 AFM
3 - EMERGENCY PROCEDURES
3.3 - ENGINE FAILURES
27/06/2019
SONAIR-S2-D-MAN-006
Rev. : A
3.3 ENGINE FAILURES
3.3.1 ENGINE FIRE / FAILURE DURING TAKE-OFF RUN
Aircraft on ground - reject take-off
1. Throttle - idle
2. Brakes - apply as needed.
With airplane stopped
3. Electric fuel pumps (both) - off
4. Fuel selector valve - off
5. Magnetos / ignition - off
6. Radio communication as required.
7. Master switches - off
8. Parking brakes - on
if required - evacuate aircraft
WARNING
Do not open the cowlings.
If fire extinguisher is used, discharge in the air intakes after
propeller stopped
NOTE
Fire extinguisher is located in baggage compartment behind
right seat if required