Rev. : A
Electrical equipment and their associated current draw are listed in the table
below. In case of emergency, calculate total load and ensure maximum 14 A.
Significant power consumers are highlighted in bold.
Component
Qty on board
Operating Current (A)
PFD
1
5
EMS
1
2
GPS COM1
1
0,5 (reception)
4 (Emission)
GPS NAV1
1
2,2
Audio Panel
1
0,8
Transponder
1
0,6 (Reception)
0.9 (Emission)
Backup Instrument
1
2
Optional Radio (COM2 function)
1
0,6 (Reception)
4,2 (Emission)
Optional Radio (NAV2 function)
1
0,6
Optional Heated Pitot
1
9,5
Stall Warning device
1
2,3
Landing light
1
1,2
Taxi light
1
1,2
Nav. / position Lights
2
0,5 (1 total)
Strobe/ anti col Lights
2
1 (2 total)
Panel lights
1
0,2
Cabin Light
1
0,3
Dimmer switch
1
0,9
Flap controller
1
0,1
Flap motor
1
3
Fuel Pumps (Main)
1
1,7
Fuel Pumps (Aux)
1
1,7
Engine starter
1
75