EasyManua.ls Logo

Sony CDP-C701ES - Safety Checks and Model Identification; Safety Check-out and Leakage Test; Model Identification Label Information

Sony CDP-C701ES
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SAFETY
CHECK-OUT
(US
Model)
MODEL
IDENTIFICATION
Specification
Label
After
correcting
the
original
service
problem,
CDP-C701ES
perform
the
following
safety
check
before
releasing
CDP-C801ES
the
set
to
the
customer:
Check
the
antenna
terminals,
metal
trim,
‘“‘metallized”’
knobs,
screws,
and
all
other
exposed
metal
parts
for
SON
Ye
move.
no.
ZZ
AC
leakage.
Check
leakage
as
described
below.
COMPACT
DISC
PLAYER
WML
LLL
LEAKAGE
TEST
The
AC
leakage
from
any
exposed
metal
part
to
earth
ground
and
from
all
exposed
metal
parts
to
any
exposed
metal
part
having
a
return
to
chassis,
must
not
exceed
0.5mA
(500
microampers).
Leakage
current
can
be
measured
by
any
one
of
three
US,
Canadian
model:
AC:
120V 60Hz
23W
methods,
AEP
model:
AC:
220—230V~50/60Hz
23W
1.
A
commercial
leakage
tester,
such
as
the
E
model:
AC:
110—120,
220—240V~50/60Hz
23W
Simpson
229
or
RCA
WT-540A.
Follow
the
manufacturers’
instructions
to
use
these
instru-
TABLE
OF
CONTENTS
ments.
2,
A
battery-operated
AC
milliammeter.
The
Data
Section
Title
Page
Precision
245
digital
multimeter
is
suitable
for
this
job.
1.
GENERAL
ldeatityine
the
Parts
cd
e-eieis
tet
haa
ae
Ra
Raekd
waco
eis
4
3.
Measuring
the
voltage
drop
across
a
resistor
by
means
of
a
VOM
or
battery-operated
AC
volt-
meter.
The
“limit”
indication
is
0.75
V,
so
2.
DISASEMBLY
analog
meters
must
have
an
accurate
low-
2:1.
“Bottom
Plate
oivcstieigoshoseium
ss
tissdewaetere
ds
5
voltage
scale.
The
Simpson
250
and
Sanwa
2-2.
“Kront
Panel
Gh):
sagen
ev
ee
esknge
sae
atae
en
ckek
9)
SH-63Trd
are
examples
of
a
passive
VOM
that
232.
-Pront:
Panel?)
cc
oscwi
dies
aedasdan
kanbts-pecseeaa
6
is
suitable.
Nearly
all
battery
operated
digital
Da.
©
PRAY
ASSY
<a
Ok
ealesiy
bal
ghee
eea
aa
een
eek
6
multimeters
that
have
a
2V
AC
range
are
suitable.
(See
Fig.
A)
3.
ELECTRICAL
BLOCK
CHECKING..................
7
4.
DIAGRAMS
To
Exposed
Metal
4-1.
Circuit
Boards
Location
..............0c0ceeeeeees
9
Parts
on
Set
.
AQ.
“Block
Didgraniicr
iets
cpear
ie
suG
ieee
screen
a
aaS
10
|
4-3,
Printed
Wiring
Boards
—Main
Section—
........
15
4-4,
Schematic
Diagram
—Main
Section—
............
19
4-5.
Printed
Wiring
Boards
—MD
Section—
..........
23
eee
4-6.
Schematic
Diagram
—MD
Section—..............
24
(0.75
VI
4-7,
Semiconductor
Lead
Layouts
....................
27
5.
EXPLODED
VIEWS
5-1.
Cabinet
Section
(C801ES)
.................0..008.
31
=
Earth
Ground
5-2.
Cabinet
Section
(C701ES)
..................0.005.
32
Using
an
AC
voltmeter
to
check
AC
leakage.
5-3.
Front
Panel
Section
....0..ccccccccucceucceuuuee
33
5-4,
Chassis
Section...........-c0cccceeueeeeeeeeennes
34
S-bo
“A
AY
SOCHON
sa
ha
cee
tar
ea
ee
a
eae
aes
35
h6..
“Optical
Pick-up
BIOck:
.2:.4¢
4540410044
Peacadasdees
36
6.
ELECTRICAL
PARTS
LIST
......................
37
—3—

Related product manuals