Sony CDX-51 - Board Modification; Electrical Adjustments

Sony CDX-51
68 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3.
BOARD
MODIFICATION
The
servo
system
was
changed
from
digital
system
to
analog
system.
3-1.
NEW/FORMER
DISCRIMINATION
Former:
1-655-449-00
New
=:
1-659-707-11
[SERVO
BOARD)
(ay
3-2.
ELECTRICAL
ADJUSTMENTS
COMPACT
DISC
CHANGER
1.
Perform
adjustments
as
given.
2.
Be
sure
to
use
the
disc
“YEDS-18”
parts
code:
3-702-101-01,
but
only
when
indicated.
3.
Power
supply
voltage:
DC14.4
V
(more
than
10
A).
4.
Adjustment
must
be
excuted
whenever
a
board
or
optical
block
is
replaced.
Focus
Offset
Adjustment
Procedure:
oscilloscope
(SERVO
BOARD]
1.
Connect
the
oscilloscope
to
SERVO
board
test
point
RF}.
2.
Put
the
set
into
play
mode
by
loading
the
disc.
3.
Adjust
the
RV13
(SERVO
board)
so
that
the
waveform
(eye
pattern)
on
the
oscilloscope
becomes
Lana.
Volt/Div:
200
mV
Time/Div:
0.5
wz
sec
\i
WHE
\
NEA
alt
ARHNMHANY
oc
Tracking
Offset
Adjustment
Procedure:
oscilloscope
eal
s_
{SERVO
BOARD)
1.
Connect
the
oscilloscope
to
SERVO
board
test
point
TE}.
2.
Put
the
set
into
play
mode
by
loading
the
disc.
3.
Press
the
Ke
or
DPE
(44
or
Pp)
button,
then,
check
the
traverse
waveform*.
4.
Adjust
RV12
(SERVO
board)
so
that
oscilloscope
reading
is
symmetrical
in
relation
to
0
+
0.05
V.
*Traverse
waveform:
This
is
the
tracking
error
wave-
form
appears
when
crossing
the
track.
VoltiDiv:
0.2
V
Time/Div:
1
msec
-
Center
OV
A
ov
B
A=B
traverse
waveform
(100
track
jump
waveform)
Tracking
Gain
Adjustment
This
adjustment
should
be
performed
after
focus
offset
and
tracking
offset
adjustments
are
completed.
Procedure:
oscilloscope
[SERVO
BOARD]
1.
Connect
the
oscilloscope
to
SERVO
board
IC11
@
pin.
2.
Put
the
set
into
play
mode
by
loading
the
disc.
3.
Press
the
Iq
or
DPE
(44
or
pp)
button,
and
adjust
the
RVI1
(SERVO
board)
so
that
the
traverse
waveform
becomes
0.3
+
0.02
V.
traverse
waveform
(100
track
jump
waveform)
Focus
Gain
Adjustment
This
adjustment
is
not
performed.
If
focus
gain
VR
RV14
is
turned,
set
to
mechanical
center.
-10—