HCD-G2BNiP/G2NiP
23
SECTION 3
TEST MODE
COLD RESET
The cold reset clears all data including preset data stored in the
memory to initial conditions. Execute this mode when returning
the unit to the customer.
Procedure:
1. In the standby status, press the [
?
/
1
] button to turn the power
on.
2. Press two buttons of [x] and [
?
/
1
] simultaneously for 2 sec-
onds.
3. When “RESET” appears, the unit enters standby status.
AUTO STANDBY MODE
This mode is used to change the automatic standby function.
With this function, the system enters standby mode automatically
in about 30 minutes when there is no operation or audio signal
output. By default, the automatic standby function is turned on.
Procedure:
1. Press the [
?
/
1
] button to turn the power on.
2. Press the [
?
/
1
] button for 2 seconds.
3. The message “AUTO STANDBY OFF” is displayed on the
fl uorescent indicator tube and the automatic standby OFF
mode is set.
4. To turn this function on, press the [
?
/
1
] button again for 2 sec-
onds.
The message “AUTO STANDBY ON” is displayed on the
fl uorescent indicator tube and the automatic standby ON mode
is set.
AUTO STANDBY TEST MODE
This mode can confi rm the automatic standby function operates
normally.
Procedure:
1. Press the [
?
/
1
] button to turn the power on.
2. Turn the [FUNCTION] knob to select excluding “TUNER”.
3. Turn the [VOLUME] knob within 5 seconds after pressing the
[
l m
TUNE –] and [
?
/
1
] buttons simultaneously.
4. The message “STATUS XXX” or “Sig*** XXX” is displayed
on the fl uorescent indicator tube.
5. When the displayed value decreases and the value becomes
“0”, the unit becomes standby status. The value doesn’t de-
crease while the audio is reproducing.
Releasing method:
Turn the [VOLUME] knob within 5 seconds after pressing the
[
l m
TUNE –] and [
?
/
1
] buttons simultaneously.
COMMON TEST MODE
This mode is used to check operations of amplifi er.
Procedure:
1. Press the [
?
/
1
] button to turn the power on.
2. Press two buttons of [
l m
TUNE –] and [
Z
] simultane-
ously for 5 seconds.
3. When the COMMON test mode is activated, “AUDIO IN1”
is displayed on the fl uorescent indicator tube and “SLEEP c”
blink on the fl uorescent indicator tube.
4. Each time the [TONE BASS]/[TONE TREBLE] knobs are
turned, or the [EQ] button is pressed on the remote command-
er, the display changes starting “EQ MAX”, “EQ MIN” and
“EQ FLAT” this order.
5. Turn the [VOLUME] knob counterclockwise, “VOLUME
MIN” is displayed on the fl uorescent indicator tube. Turn the
[VOLUME] knob clockwise, “VOLUME MAX” is displayed
on the fl uorescent indicator tube.
Releasing method:
Press the [
?
/
1
] button to turn off the system.
PANEL TEST MODE
This mode is used to check the fl uorescent indicator tube, LED,
model, destination, software version and key.
Procedure:
1. Press the [
?
/
1
] button to turn the power on.
2. Press two buttons of [
l m
TUNE –] and [
u
] simultane-
ously for 5 seconds.
3. All segments on the fl uorescent indicator tube, [STANDBY]
LED light up.
4. Press the [
l m
TUNE –] button, the model and destination
are displayed on the fl uorescent indicator tube.
5. Press the [
l m
TUNE –] button again, MC version is dis-
played on the fl uorescent indicator tube.
6. Each time [
l m
TUNE –] button is pressed, the display
changes starting from MCS version, GC version, USBL ver-
sion, NWA version, NWD version, NWM version, CD version,
CDD version, CDMA version, CDMB version, BDA version,
BDB version, ST version, TA version and TM version this or-
der, and returns to the MC version display.
7. When [
x
] button is pressed while the MC version is displayed,
year, month and day of the software creation is displayed.
When [
x
] button is pressed again, the display returns to the
MC version display.
8. Press the [
M
L
TUNE +] button, the key test mode is acti-
vated and “K 0 J0 V0” is displayed on the fl uorescent indicator
tube.
9. Each time a button is pressed, “K” value increases. However,
once a button is pressed, it is no longer taken into account.
All keys are pressed, display becomes “K10” .
10. “J” value increases 0, 1, 2 ... if turn the [TONE BASS], [TONE
TREBLE] or [FUNCTION] knobs clockwise, or it decreases 9,
8, 7 ... if turn the knob counterclockwise.
11. “V” value increases 2, 4, 6 ... if turn the [VOLUME] knob
clockwise, or it decreases 8, 6, 4 ... if turn the knob counter-
clockwise.
Releasing method:
Press two buttons of [
l m
TUNE –] and [
u
] simultaneously,
or disconnect the power cord.
CD SHIP MODE
This mode moves the optical pick-up to the position durable to
vibration. Use this mode when returning the set to the customer
after repair.
Procedure:
1. Press the [
?
/
1
] button to turn the power on.
2. Turn the [FUNCTION] knob to select “CD”.
3. Press the [
Z
] button for 5 seconds.
4. After blink “STANDBY”, “LOCK” is displayed, disconnect
the power cord.
CD SHIP MODE & COLD RESET
This mode is used to perform CD ship mode and cold reset simul-
taneously.
Procedure:
1. Press the [
?
/
1
] button to turn the power on.
2. Press two buttons of [
M
L
TUNE +] and [
Z
] simultane-
ously for 5 seconds.
3. After blink “STANDBY”, “LOCK” is displayed, disconnect
the power cord.

Table of Contents