6-4. SKEW Adjustment
1) Stand the BU adjustment jig in the upright position.
2) Connect the jitter meter to the BU adjustment jig.
(Refer to section “4-2. Jitter Meter of “4. Equipment
Connection.)
3) Insert the test CD (SCD-2700).
4) Click the [SKEW Adjust] button on the Adjustment Menu
screen of the “Dencho for DDX-G2100”.
5) Confirm that the SKEW Adjust screen is displayed.
(Fig. 6-4-1)
Fig. 6-4-1