Items Relating to Prerolling (Nos. 401 to ...)
Item number Item Setting Function
401 FUNCTION MODE
AFTER CUE-UP
[stop]
still
Selects the operation mode that the VTR changes to after
completing a cue up operation.
stop: Enters stop mode.
still: Enters still-picture mode (search mode).
Note
When setting the standard constant on the editor and
control the unit, set to “stop”.
403 CUEUP BY TC capstan only
[reel/capstan]
This setting is only active when item 602 is set to “TC” or
“UBIT”.
capstan only: The tape runs with the pinch ON state during
cue up. (The maximum tape speed is ten times normal
tape speed.)
reel/capstan: The tape runs with the pinch OFF state
during cue up. When the tape nears the cue up point
and tape speed drops to slow, the pinch turns ON.
404 CUEUP BY CTL [capstan only]
reel/capstan
This setting is only active when item 602 is set to “CTL”.
capstan only: The tape runs with the pinch ON state during
cue up. (The maximum tape speed is ten times normal
tape speed.)
reel/capstan: The tape runs with the pinch OFF state during
cue up. When the tape nears the cue up point and tape
speed drops to slow, the pinch turns ON.
When this unit is controlled by an editor (BVE-2000/BVE-
9100, etc), and the setting is “reel/capstan”, cue up
operations are done at high speed.
Select “capstan only” when editing precision has priority.
405 CUE MENU
DEFAULT MODE
select
[page mode]
extend mode
Selects the default mode when the CUE menu is opened.
page mode: PAGE mode
extend mode: EXTEND mode
406 CUE MENU
PREROLL OFFSET
[0 sec]
30 sec
Sets the preroll time for a cueing up operation from the
CUE menu.
407 AUTO REWIND [off]
on
s.rew
Selects the rewind mode for the end of the tape.
off: The tape transport stops at the end of the tape.
on: The tape is automatically rewound from the end of the
tape.
s.rew: The tape is automatically rewound from the end of
the tape.
For HDCAM SR L cassettes, the tape is rewound
smoothly to its beginning in SOFT REWIND mode.
(The cassette is not automatically ejected.)
For cassettes other than HDCAM SR L, SOFT
REWIND mode is disabled and the tape is rewound in
standard REW mode.
408 AUTO CUE UP [off]
on
Selects whether or not to cue up when switching from
standby-off to standby-on.
off: No cue-up.
on: Cue up to the time code immediately before switching
to standby-off.

Table of Contents

Other manuals for Sony SRW-5800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sony SRW-5800 and is the answer not in the manual?

Sony SRW-5800 Specifications

General IconGeneral
BrandSony
ModelSRW-5800
CategoryVCR
LanguageEnglish

Related product manuals