Advanced
Recording
Operations
Adjusting
Bias
and
Recording
-
Level
Calibration
Automatically
Since
there
are
many
different
types
of
cassettes
on
the
market,
your
tape
deck
automatically
sets
the
appropriate
equalization
characteristics
and
bias
current
for
each
tape type
(ATS:
Automatic
Tape
Selection).
However,
you
can
get
better
recording
results
by
doing
the
automatic
bias
current
and
the
recording
level
calibration.
You
can
do
automatic
calibration
on
either
deck
(TC-WA8ESA
/WE8055
only)
or
only
on
deck
B
(on
all
other
models).
DECK
A
/
DECK
B
PAUSE
11
<J
/
C>
PAUSE
II
1
Insert
the
cassette
you
want
to
record
on
into
deck
B
or
into
either
deck
(TC-WA8ESA
/WE805S
only).
Make
sure
the
record-protect
tabs
on
the
cassette
have
not
been
removed.
2
Press
DECK
A
or
DECK
B
on
the
TC-WA8ESA
and
WE805S,
or
AUTO
CAL
on
all
other
models
until
“CAL”
appears
in
the
display.
:
3
Press
>
or
<J
to
select
the
side
of
the
tape
to
be
recorded.
To
select
Press
The
front
side
>
The
reverse
side
<a
4
Press
PAUSE
fl
to
start
the
automatic
calibration
procedure.
The
automatic
calibration
procedure
starts
(i.e.,
recording
test
tones,
rewinding,
and
playing
back).
During
the
calibration,
the
counter
changes
from
9
to
0.
cat
0
(ED
CALS
When
the
automatic
calibration
procedure
ends,
the
tape
rewinds
to
the
original
position,
the
counter
returns
to
normal
and
the
tape
deck
stops.
5
Start
the
actual
recording
(see
page
6).
To
cancel
the
automatic
calibration
function
Press
@
on
the
deck
you're
using.
if
“[A]”
or
“[B)"
on
the
TC-WA8ESA
and
WE805S
or
“CAL”
on
all
other
models
flashes
continuously
The
automatic
calibration
procedure
has
been
interrupted
by:
The
end
of
the
tape.
Reverse
the
tape
direction
or
rewind
the
tape
to
a
new
position
that
allows
recording
of
the
test
tone.
Damaged
tape
or
dirty
heads.
Change
the
cassette
or
clean
and
demagnetize
the
heads
(see
page
19).
Updating
the
calibration
setting
If
you
insert
a
cassette
and
“[A]
CAL”
or
“CAL
[B]”
on
the
TC-WA8ESA
and
WE805S
or
“CAL”
on
all
other
models
appears
in
the
display,
it
means
that
automatic
calibration
data
in
that
deck
for
that
tape
type
(I,
II
or
IV)
exists.
However,
we
recommend
that
you
repeat
the
automatic
calibraion
procedure
each
time
you
insert
a
new
cassette
since
cassettes
of
the
same
type
also
vary
in
their
characteristics.
Before
recalibrating,
be
sure
to
turn
off
“[A|
CAL”
or
“CAL
[B]”
on
the
TC-WA8ESA
and
WE805S
or
“CAL”
on
all
other
models
by
pressing
DECK
A
or
DECK
B
on
the
TC-WA8ESA
and
WE805S
or
AUTO
CAL
on
all
other
models.
Then
start
from
Step
2
of
the
automatic
calibration
procedure.
11

Related product manuals