UHF Wireless Microphone Package
UHF Synthesized Transmitter
UHF Synthesized Wireless Microphone
UHF Synthesized Diversity Tuner
Operating Instructions
Before operating the unit, please read this manual thoroughly
and retain it for future reference.
UWP-D21/D22/D26/D27
UTX-B40
UTX-M40
UTX-P40
URX-P40
URX-P41D
5-042-114-11 (1)
© 2022 Sony Corporation

Questions and Answers

  • M
    Michael FloresNov 24, 2025
    Why is there sound interruption or noise with my Sony URX-P40?
    • J
      Johnny LamNov 24, 2025
      To resolve sound interruption or noise with your Sony Microphone system, ensure that the channel setting is the same on both the transmitter and tuner. Avoid using the same channel for two or more transmitters. If using multiple transmitters, configure them to different channels within the same channel group to prevent signal interference. Use channels separated by at least two channels (250 kHz). Also, adjust the output level on the tuner and the reference input level on the camcorder. Move the transmitter and tuner further apart, and turn off any unused tuners. If you are using a camcorder, be aware that beeping noises, crackling or squealing sounds, or hum noise can occur due to interference from the camcorder's media access, Wi-Fi, or LCD backlight. Adjust the output level and referenc...
  • M
    micheleortizAug 23, 2025
    How to fix no sound on Sony Microphone system?
    • G
      Garrett ContrerasAug 23, 2025
      If your Sony Microphone system isn't producing any sound, make sure the channel setting on the transmitter matches the tuner. Confirm the transmitter is on and reduce the distance between it and the tuner if the transmission output is weak. Ensure the transmitter is set to microphone input, not line level. The compander mode setting on both devices should be the same. Also, check if the transmitter is muted and change the MUTE SETTING if it is set to PTT HOLD.
  • K
    Karen YoungAug 27, 2025
    How to fix a Sony URX-P40 Microphone system that does not turn on?
    • E
      Erin WallaceAug 27, 2025
      If your Sony Microphone system is not turning on, ensure the batteries are inserted with the correct polarity. Replace low batteries with new ones. Clean any dirt from the battery terminals and the battery compartment with a cotton swab. If using battery power, make sure batteries are inserted and the power source is set to 'BATT ONLY'. If using the SMAD-P5, check that it is correctly connected to the camera or tuner and that the power supplies for the tuner and camera are correctly linked.
  • C
    Crystal BakerAug 27, 2025
    What to do if there is no sound from my Sony Microphone system?
    • D
      Derek PotterAug 27, 2025
      If there is no sound from your Sony Microphone system, verify that the channel setting is the same on both the transmitter and tuner. Confirm that the transmitter is on and reduce the distance between the transmitter and tuner. Ensure the transmitter is set to microphone input, not line level. The compander mode setting must be the same on both devices. Check if the transmitter is muted and release it by pressing the POWER/MUTE button. Review the MUTE SETTING menu and audio output connector settings. If using the SMAD-P5, ensure the Analog/Digital switch is correctly set. For microphones connected to the MIC INPUT, configure the microphone setting in the MIC SELECT menu to match the microphone type.
  • W
    William BlevinsAug 29, 2025
    Why is the noise louder when connected with SMAD-P5 on my Sony URX-P40 Microphone system?
    • H
      hunterscottAug 29, 2025
      To resolve the issue of louder noise when connected with SMAD-P5 compared to the XLR-BMP conversion output cable on your Sony Microphone system, adjust the reference input level and reference recording level of the camcorder, or adjust the OUTPUT LEVEL on the tuner to set the appropriate audio level.
  • D
    David HowardSep 18, 2025
    How do I fix the attenuator settings on my Sony URX-P40?
    • M
      mccartyrickSep 18, 2025
      If the attenuator cannot be set on your Sony Microphone system, the GAIN MODE menu may be set to AUTO GAIN, or the INPUT LEVEL menu may be set to LINE. Change the GAIN MODE menu and INPUT LEVEL menu settings.
  • R
    Rebecca MurilloSep 15, 2025
    How to troubleshoot the infrared transmission on a Sony URX-P40?
    • A
      Anthony SolisSep 15, 2025
      If the transmitter channel on your Sony Microphone system cannot be set with infrared transmission, reduce the distance between the infrared receptor on the transmitter and the infrared transmission port on the tuner to within about 20 cm (8 in.). Also, minimize interference from infrared communications or direct sunlight by placing the transmitter and tuner as close as possible. Ensure that the SYNC MODE menu setting is set to IR.
  • B
    Brian BassSep 17, 2025
    How to troubleshoot NFC communication on a Sony Microphone system?
    • T
      Teresa BauerSep 18, 2025
      If the transmitter channel of your Sony Microphone system cannot be set via NFC communication, ensure the N-Marks of both units are facing each other and are approximately 5 mm apart, with no metallic objects nearby. Also, verify that the SYNC MODE menu setting is NFC.
  • D
    dale77Sep 7, 2025
    Why transmitter channel cannot be set via NFC communication on Sony Microphone system?
    • S
      Suzanne HarrisSep 7, 2025
      If you are unable to set the transmitter channel on your Sony Microphone system via NFC communication, place the N-Marks approximately 5 mm from each other, ensuring they are facing each other and that there are no metallic or other objects nearby.
  • S
    steinjeffreySep 5, 2025
    What to do if Sony Microphone system does not turn off?
    • G
      Gabrielle BowenSep 5, 2025
      If your Sony Microphone system does not turn off, release the locked status in the POWER LOCK menu. Alternatively, if the unit is set so that power cannot be turned on/ off using the POWER/MUTE button, set the POWER/MUTE menu to POWER/MUTE, or turn the unit off using the POWER button.

Summary

Name and Function of Parts

Body-pack Transmitter (UTX-B40) Parts

Identifies and describes the components of the UTX-B40 body-pack transmitter.

Power Supply

Inserting Batteries

Provides instructions on how to correctly insert AA batteries into the devices.

USB Power Supply

Explains how to power the devices using a USB connector.

Tuner Settings

Setting the Receive Channel

Guide on selecting the appropriate channel group and number for reception.

Transmitter Settings

Setting the Transmit Channel

Guide on selecting the appropriate channel group and number for transmission.

Troubleshooting

Unit Power Issues

Solutions for problems related to the unit not turning on.

Audio Signal Problems

Troubleshooting steps for weak, distorted, or noisy audio signals.

Channel Setting Issues

Resolving problems with setting or receiving channels.

Sony URX-P40 Specifications

General IconGeneral
Audio Frequency Response20 Hz to 20 kHz
Tuning Steps25 kHz
Frequency Range470 to 608 MHz
ModulationFM
Signal-to-Noise Ratio> 100 dB
Operating RangeUp to 100 m (328 ft)
Distortion< 0.5%
Antenna TypeDiversity Antenna
Operating Temperature0°C to 50°C
Storage Temperature-20°C to 60°C
Battery TypeAA
Power SupplyDC 3V

Related product manuals