EasyManua.ls Logo

Sony XR-83A80L - Page 14

Sony XR-83A80L
261 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Smart Core
Red LED blinking
count
Error Name Retry Permission Times
*1
Note
2x MAIN_POWER
STDWN_RTRY_LIMIT_MAINPOWR = 1
3x
DC_ALERT (5V) STDWN_RTRY_LIMIT = 2
AUD_ERR STDWN_RTRY_LIMIT = 2
4x
LD_ERR STDWN_RTRY_LIMIT = 2
BCM_ERR STDWN_RTRY_LIMIT = 2
5x P_ID_ERR STDWN_RTRY_LIMIT = 2
6x BACKLIGHT STDWN_RTRY_LIMIT = 2
7x TEMP_ERR STDWN_RTRY_LIMIT = 2
8x 4KBE_ERR STDWN_RTRY_LIMIT = 2
14
Number of off/on action during the
error shutdown is recorded to
STDWN_OFFON_CNT
*2
.
Number of off/on action for MAIN_POWER
shutdown is recorded to
STDWN_OFFON_CNT_MAIN_POWER
*2
.
*1) If STDWN_OFFON_CNT <= STDWN_RTRY_LIMIT, and STDWN_OFFON_CNT_MAIN_POWER <= STDWN_RTRY_LIMIT_MAINPOWR, you can turn the set on
by a remote/power key. At this time, if the error occurs again, the STDWN_OFFON_CNT is incremented by 1.
*2) When the main micro operates normally for STDWN_OFFON_CLR = 60 minutes, STDWN_OFFON_CNT and STDWN_OFFON_CNT_MAIN_POWER are cleared.
Retry Limitation by Remote/Power Key
SELF DIAGNOSIS FUNCTION
SYSSET
2023/11/2806:39:49(GMT+09:00)

Other manuals for Sony XR-83A80L

Related product manuals