7
TECHNICAL SPECIFICATIONS
BSS-134
CHAP.- 2
2.5 Notes on using the machine
IT IS FORBIDDEN TO:
1. Amend the cycle of the machine;
2. Work different products from those indicated;
3. Replace or amend the speed of the machine components;
4. Replace pieces with non-original spare parts;
5. Amend the electric connections to by-pass the safety devices;
6. Remove or amend the protection sumps;
7. Use the machine in environments with explosive and/or aggressive atmosphere.
The non-admitted use of the machine entails the immediate expiring of the warranty.
2.6 Technical data
- Machine weight: ........................................................................................................... ~ 720 Kg
- Installed electric power: ........................................................................................... 5,7 Kw/ 10A
- Power supply voltage: .................................................. 400V/50Hz (unless otherwise specifi ed)
- Compressed air working pressure:...................................................................................... 6 bar
- Compressed air consumption:.................................................................................... 740 Nl/min
- Acoustic pressure: ............................................................................................................... 70 dB
- Working temperature: .......................................................................... between +5°C and +40°C
- Throughput:................................................. Vert-bag up to 2 kg.: . 32 – 35 packs/minute approx.
Vert-bag 3 kg.: .. 30 – 32 packs/minute approx
N.B.: the maximum electric and pneumatic consumption, as well as productivity, should be considered
as variables depending on: type of boxes, packages, products to be processed, consumables being
used and operator’s capacity.