Operating Instructions
10040N AUTORANGING MULTIMETER
Multímetro de Rango Automático 10040N
Instrucciones de uso
Contents Made in China
Product distributed by Southwire Company, LLC
One Southwire Drive, Carrollton, GA 30119
©2014 Southwire Company, LLC. All rights reserved.
southwiretools.com
1-855-SW-T00LS
Toll Free Technical Help
Línea de Ayuda Técnica Gratuita
Scan for warranty informaon
and to access our mobile site.
Escanea para información de garana
y acceso a nuestro sio móvil.
2/15 Rev. 1
10040N manual
Auto
Power
Off
MODE
RANGE
HOLD
REL
COM
10A
For
30sec.
MAX
every
15 min
FUSED
! !
CAT III 600V
Question and Answer IconNeed help?

Do you have a question about the Southwire 10040n and is the answer not in the manual?

Southwire 10040n Specifications

General IconGeneral
Model10040n
CategoryMultimeter
AC Voltage600V
DC Voltage600V
AC Current10A
DC Current10A
Resistance40 MΩ
ContinuityYes
Diode TestYes
Audible ContinuityYes
DisplayLCD
Battery Type9V
Safety RatingCAT III 600V

Summary

Introduction, Safety, and Specifications

Safety Warnings and Input Limits

Critical safety precautions, hazardous voltage warnings, and maximum input ratings.

Operation - Controls and Functions

Operation - Voltage and Current Measurements

AC/DC Voltage Measurement

Step-by-step guide for measuring AC and DC voltage safely.

AC/DC Current Measurement

Procedure for measuring AC and DC current, including safety warnings and connection details.

Operation - Resistance, Continuity, Diode, Capacitance

Operation - Frequency, Duty Cycle, Temperature, Voltage Detection

Operation - Battery and Fuse Replacement

Battery Replacement

Steps to safely remove and replace the multimeter's 9V battery.

Fuse Replacement

Procedure for replacing the internal fuses, specifying types and ratings.