9SC-CF & SC-MP Service Manual
GFCI Trips!
3 If problem is not solved yet,
disconnect incoming power
lines.
If GFCI still trips, there must be
a cable problem.
Call an electrician!
4 If GFCI stops tripping, replace
GFCI.
5 If GFCI trips again, replace
Spa Pack.
If GFCI continues to trip carry out the following tests to correct
the problem:
1 If GFCI is properly connected, but
still tripping, (or Jumper #1 is set in
LC mode for 120 VAC systems),
unplug all outputs
including the
two blades of
the heater
and light cord.
2 If GFCI still trips, replace Spa Pack.
If it stops tripping, reconnect one
component at a time until GFCI
starts tripping. Replace defective
component.