34 SC-CF & SC-MP Service Manual
HL Error Condition
Press any key between each step to reset the system.
Power may remain On.
1 Take water temperature with
digital thermometer.
2 If reading is below 119°F:
a- Check if heater barrel feels hot.
If it's hot, verify if anything is
obstructing water flow
(closed valves or dirty filter).
b- If HL error condition persists,
replace Spa Pack.
3 If reading is 119°F or higher:
Proceed to following page if
keypad display shows correct
temperature.
Proceed to page 36 if keypad
doesn't show correct tempera-
ture.
The HL error condition is related to the Hi-Limit sensor.
Steady message: Means system has shut down heater because water
temperature at the heater has reached 119ºF.
Blinking message: Means except for the Smart Winter Mode, system has shut
down because water temp. in the spa has reached 112ºF.