54 SC-CF & SC-MP Service Manual
Spa Light Does Not Work!
If spa light is not working, carry out the following tests to correct
the problem:
It is important to measure voltage when light is connected to pack.
Power must remain On.
2 If light still isn't working, verify if
"Light" indicator appears on
keypad display when you press
Light key.
1 The first step is to replace the
spa's light bulb.
3 If "Light" indicator doesn't appear,
use a spare keypad to verify if spa
keypad is defective.
If it is, replace keypad.
If not, replace Spa Pack.
5 If you aren't getting a voltage
reading, replace light fuse on
the board.
6 If problem persists, replace
Spa Pack.
Light fuse
4 If "Light" indicator appears, but
light still isn't working, remove
plastic cover and measure
voltage between two light wires
on the board.
If you get 12 VAC, replace light
socket.
"Light"
indicator